Send Message
Home ProductsTower Internals

Packed Tower Internals Air Inlet Uniform Distributor 316l Material

I'm Online Chat Now

Packed Tower Internals Air Inlet Uniform Distributor 316l Material

Packed Tower Internals Air Inlet Uniform Distributor 316l Material
Packed Tower Internals Air Inlet Uniform Distributor 316l Material Packed Tower Internals Air Inlet Uniform Distributor 316l Material

Large Image :  Packed Tower Internals Air Inlet Uniform Distributor 316l Material

Product Details:
Place of Origin: China
Certification: ISO 9001
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Negotiation
Packaging Details: pallet, wooden box
Delivery Time: 3-5 days
Payment Terms: L/C, T/T
Supply Ability: 99 units per month

Packed Tower Internals Air Inlet Uniform Distributor 316l Material

Description
Product: Packed Tower Internal Air Inlet Uniform Distributor Material: 316L
Plate Thickness: 3 Mm, 4 Mm, 5 Mm, 6 Mm, Etc. Flow Rate: As Per Designed Range
Advantage: Uniform Distribution Design Service: Yes
Application: Packing Tower Type: Plate Bending
Size: Any Size As Per Order Position: With Air Inlet Pipe
High Light:

packed tower internals

,

316l material tower internals

,

air inlet uniform distributor tower internals

 

Packed tower internal air inlet uniform distributor 316L material

 

 

1. Hualai factory packed tower internal air inlet uniform distributor,

 

Packed tower is a mass transfer equipment of gas-liquid two-phase, and its mass transfer efficiency is determined by whether the gas-liquid two-phase can be fully contacted, and one of the keys to the full contact of gas-liquid two-phase is the uniform distribution of gas.

 

2. Hualai factory Tower internal Products,

 

Type Advantage Disadvantage Scope
Bubble cap tray Mature, wide operation range Complex structure, high resistance and low production capacity Some special towers requiring good flexibility of operation
Floating valve tray High efficiency and wide operation range Using stainless steel, the float valve is easy to fall off The separation requirement is high and the load changes greatly; Crude atmospheric fractionator
Sieve tray High efficiency and low cost The installation should be horizontal, easy to block and narrow operation range The separation requirement is high, and there are many trays; Propylene tower in chemical industry
Jet tray Simple structure and large production capacity Narrow operation range and low efficiency Flash tower with lower separation requirements
Slant-Hole Tray Large production capacity and high efficiency The operating range is narrower than that of valve tower and bubble cap tower High separation requirements and large production capacity

 

3. The specific requirements for the air inlet distributor.

  1. The uniform distribution of gas is good, that is, the gas flow into the packed bed can flow into the packed bed evenly after the pre distribution of the inlet structure;

  2. The flow resistance is small;

  3. It takes less space;

  4. The liquid can fall freely, which is beneficial to the mass transfer of two phases;

  5. The structure is simple and easy to install.

Among these requirements, good uniformity and low resistance are the main ones.

 

4. Relationship between gas distribution and packed bed

 

The initial gas distribution should be considered in the low pressure drop packed bed. Horner takes the pressure drop less than 8.3 mm H2O / m as the boundary; The initial gas distribution should be considered in the packed column with shallow bed. Many scholars regard the bed height with height diameter ratio less than 0.5-1 as the boundary line to distinguish the shallow bed; Even if the height diameter ratio of the packing layer is greater than 1, the initial gas distribution is also very important; The main reason is the uneven distribution of gas flow into the packed bed. Therefore, the study of gas distribution in packed tower is mainly to study the pre distribution of gas and the design method of inlet structure to achieve uniform pre distribution.

 

5. Packed column classification - view of gas distribution requirements

 

According to the requirements of uniform distribution of gas flowing into packed bed, the packed tower can be divided into four types (1) Large diameter shallow bed packed tower; (2) Medium and small diameter shallow bed packed tower; (3) Large diameter packed tower; (4) Medium and small diameter packed tower. In the above classification, the bed with height diameter ratio less than or equal to 1 is shallow bed, and tower diameter greater than 2 m is large diameter. (1) Due to the worst distribution ability of the packed bed itself, the gas distributor is the most ideal way to realize the uniform distribution of the air flow in the bed almost completely by the pre distribution of the inlet structure. (2) Due to the low bed height, the uneven initial distribution can not be transformed into uniform distribution in the bed. Therefore, the uniform pre distribution of gas flow into the bed is also required to improve the mass transfer efficiency. As the diameter of this kind of tower is small, it is not difficult to make the inlet air evenly pre distributed as long as the inlet pipe structure is designed reasonably or the measures such as adding uniform grid are adopted. For the other two types of tower, especially (4), due to the large height diameter ratio of the bed, it has better uniform distribution performance, so the distribution requirements can be lower. However, special attention should be paid to the influence of inlet pipe structure, packing support plate and bed structure on the uniform distribution performance.

 

6. Hualai workshop for tower internals

 

Packed Tower Internals Air Inlet Uniform Distributor 316l Material 0

 

Welcome your contact with your private tower internals plan or ideas!

Contact Details
Beijing Silk Road Enterprise Management Services Co.,LTD

Tel: 15112670997

Send your inquiry directly to us (0 / 3000)